Double flow heat pump: CINEFFI LC – Low energy – DESIGNED FOR CINEMAS
The CINEFFI LC air treatment system is specifically designed for the ventilation, heating and air conditioning of cinema halls. These reversible double flow heat pumps include various equipment to use energy more efficiently and reduce operating costs for cinemas.
As an ErP 2018 ready unit, the CINEFFI LC meets the European regulatory obligations as per Directive 2009/125/EC on the ecodesign of ErPs (Energy related Products).
Description
The CINEFFI LC air treatment system is specifically designed for the ventilation, heating and air conditioning of cinema halls. These reversible double flow heat pumps include various equipment to use energy more efficiently and reduce operating costs for cinemas.
As an ErP 2018 ready unit, the CINEFFI LC meets the European regulatory obligations as per Directive 2009/125/EC on the ecodesign of ErPs (Energy related Products).
Double flow rooftop heat pump & air conditioner with rotary heat exchanger covered by a 20-year anti-corrosion guarantee
The ETT packaged unit is delivered ready to operate. Its full aluminium structure (frame & casing) ensures an excellent corrosion protection (20-year anti-corrosion guarantee).
The ETT unit can be installed either at ground level or on a roof. ECODESIGN involves DECONSTRUCTION: ETT units are 98% recyclable (re-use and recycling rates based on ULTI+ 21)
The CINEFFI LC heat pump with heat exchanger operates as a reversible heat pump:
- Source: outside air + exhaust air (in recovery mode)
- Treated fluid: outside air + hygienic fresh air
The unit offers several operating modes:
- Heat pump
- Cooling
- Free Cooling: cooling with outside air, without thermodynamics
- Recirculation
The CINEFFI LC offers several operating modes:
The ETT packaged unit comprises 4 different sections:
- The separate technical section houses the refrigeration components, the electrical board and the control components.
- The internal section ensures air change and air treatment.
- The exhaust air section allows heat recovery and/or removal on exhaust air (depending on the operating mode).
- The rotary heat exchanger section allows heat recovery.
Available options
- Motorised external damper on supply air (2006/42/EC Directive)
- Painting
Acoustics
- Technical section acoustic insulation using STOPFLAM flexible fire-proof polyurethane foam
- Fresh air cowl acoustic insulation
- Compressors acoustic jackets
Air handling
- Magnehelic dial pressure gauge at each filtration stage
- Analogue air flow controller (AFC), air flow rate indication and measurement
- Filters fouling analogue control (FFAC)
- Actuating smoke detector with battery back-up
- Epoxy coating on fans & vinyl coating on exchangers
- Supply air fan max. available pressure: 600 Pa
- Exhaust air fan max. available pressure: 400 Pa
- Operation with all recirculated air or all fresh air (not available for public access buildings)
- G4 refillable filters
- 1 set of spare 98 mm G4 filters
- 98 mm F6 to F9 opacimetric filters
- 1 set of spare 48 mm G4 filters
Thermodynamics
- HP and LP pressure gauges
- Electronic expansion valves
Thermal exchangers
- 2-stage electric heater
- Triac
- 2-row hot water coil with analogue frost protection thermostat
- Vinyl coating on hot water coil
Installation
- Adjustable aluminium ventilated roof curb
- Adjustable aluminium connection roof curb
- 200 or 400 mm aluminium feet
Electrical
- Unit global energy metering
Control
- Banning of Free Cooling using specific humidity comparison
- Humidity probe (for external humidifier control)
Recovery
- Epoxy protection on rotary heat exchanger