Double flow heat pump: FR CH RE V

The FR CH RE V is a vertical double flow heat pump specially designed for ventilation, heating and air conditioning in buildings with variable occupancy, such as entertainment halls and community halls. This self-contained unit features specific components to maximise energy savings.

FRCHREV

Description

Double flow heat pump with 20-year anti-corrosion guarantee

The FR CH RE V is the perfect ventilation and air conditioning solution for cinemas or entertainment halls. It offers maximum air quality while ensuring acoustic comfort. This vertical double flow heat pump is delivered ready to operate and can be installed either on a rooftop or at ground level, depending on your needs. Thanks to its full aluminium structure (frame & casing), this unit is covered by a20-year guarantee against corrosion.

The FR CH RE V operates as a reversible heat pump:

  • Source: outside air + inside air (in recovery mode)
  • Treated fluid: inside air + hygienic fresh air

The unit offers several operating modes:

  • Heat pump
  • Cooling
  • Free Cooling: cooling with outside air, without thermodynamics

Legend key

In these modes, the unit can operate:

  1. With all recirculated air
  2. With all fresh air/all exhaust air
  3. With mixed-air

The unit ensures air exhaust and fresh air modulation without indoor pressure change.

The ETT packaged unit comprises 3 different sections:

  1. The separate technical section houses the refrigeration components, the electrical board and the control components.
  2. The internal section ensures air change and air treatment.
  3. The exhaust air section allows heat recovery and/or removal on exhaust air (depending on the operating mode).

FR CH RE V

Available options

Frame – Casing

  • Motorised external damper on supply air (2006/42/EC Directive)
  • Painting
  • Delivery in three blocks (sheet metal work assembly and electrical connection shall be done by the customer)

Acoustics

  • Technical section acoustic insulation using STOPFLAM flexible fire-proof polyurethane foam
  • Fresh air cowl acoustic insulation
  • Compressors acoustic jackets

Air handling

  • Pressure gauge at each filtration stage
  • Analogue air flow controller (AFC), air flow rate indication and measurement
  • Filters fouling analogue control (FFAC)
  • Actuating smoke detector with battery back-up
  • Epoxy coating on fans & vinyl coating on exchangers
  • Supply air fan max. available pressure: 600 Pa
  • Exhaust air fan max. available pressure: 400 Pa
  • Operation with all recirculated air or all fresh air (not available for public access buildings)
  • G4 refillable filters
  • 1 set of spare 98 mm G4 filters
  • 98 mm F6 to F9 opacimetric filters

Thermodynamics

  • HP and LP pressure gauges
  • Electronic expansion valves

Thermal exchangers

  • 2-stage electric heater
  • Triac
  • 2-row hot water coil with analogue frost protection thermostat
  • Vinyl coating on hot water coil
  • Exhaust air fan max. available pressure 400 Pa
  • Operation with all recirculated air or all fresh air (not available for public access buildings)
  • G4 refillable filters
  • 1 set of spare 98 mm G4 filters
  • 98 mm F6 to F9 opacimetric filters

Electrical

  • Unit global energy metering

Control

  • Banning of Free Cooling using specific humidity comparison
  • Humidity probe (for external humidifier control)

Installation

  • 200 or 400 mm aluminium feet

Communication

  • myETTvision
  • ETT TouchScreen remote touchscreen display
  • Modbus RS485
  • Modbus IP
  • BACnet IP
  • LonWorks
  • Konnex

Download the brochure

Commercial brochure

Commercial brochure

FR CH RE V